Gai-tronics 12584-002 I/O Control Module User Manual

Browse online or download User Manual for Communication Gai-tronics 12584-002 I/O Control Module. GAI-Tronics 12584-002 I/O Control Module User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Pub. 42004-388B
GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model 12584-002 I/O Control Module
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
The Model 12584-002 I/O Control Module is designed to monitor contact closure devices connected to its
input, and to turn devices on or off that are connected to its output. It operates as a slave device reporting
to a system master controller via a serial data line connection. The master controller is programmed to
recognize the I/O Control Module and process the data information received from it.
Typically, the system master controller is a
computer or a GAI-Tronics Model 10959
Series Audio Messenger Interface (AMI). In
special applications, the system master
controller can be another I/O Control Module
that is reprogrammed with custom software.
In general, the Model 12584-002 I/O Control
Module provides the following features:
Digital Input Monitoring
The I/O Control Module can monitor up to 32
voltage-free contact inputs. The contacts can
be normally open or closed. Additionally, they
can be momentary or maintained type
activation. The programming of the system
master controller defines how each input is activated. Each input is individually programmed for the type
of activation switch and the resulting event.
Analog Input Monitoring
The I/O Control Module monitors up to eight analog voltage inputs from 0 to +5 V dc. Each input is
individually programmed to activate on a pre-programmed voltage threshold level.
N
OTE: This feature is not available when an AMI is acting as the master controller device.
Figure 1. Model 12584-002 I/O Control Module
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - General Information

Pub. 42004-388B GAI-Tronics Corporation P.O. Box 1060, Reading, PA 19607-1060 USA 610-777-1374  800-492-1212  Fax: 610-796-5954 VISIT WWW.G

Page 2 - Output Control

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 10 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-38

Page 3 - DIP Switch S4

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 11 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-38

Page 4

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 12 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-38

Page 5

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 13 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-38

Page 6

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 14 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-38

Page 7 - Installation

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 15 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-38

Page 8

(Rev. 10/06)WarrantyEquipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that anyGAI-Tronics equipment supplied he

Page 9

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 2 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-388

Page 10 - Pub. 42004-388B

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 3 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-388

Page 11

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 4 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-388

Page 12

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 5 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-388

Page 13 - Terminal Labeled Function

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 6 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-388

Page 14

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 7 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-388

Page 15 - Specifications

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 8 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-388

Page 16 - Return Policy

Pub. 42004-388B Model 12584-002 I/O Control Module Page: 9 of 15 \\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-388

Comments to this Manuals

No comments