Gai-tronics 10962-001, 10962-002 AMI Redundant Controller Modu User Manual

Browse online or download User Manual for Communication Gai-tronics 10962-001, 10962-002 AMI Redundant Controller Modu. GAI-Tronics 10962-001, 10962-002 AMI Redundant Controller Modules User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Pub. 42004-708L2B
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
V
ISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
GAI-TRONICS® CORPORATION
A HUBBELL COMPANY
Model 10962-001 and 10962-002
AMI Redundant Controller Modules
Confidentiality Notice
This manual is provided solely as an operational, installation, and maintenance guide and contains
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
The Model 10962-001 and 10962-002 AMI Redundant Controllers (ARC) are designed for GAI-Tronics
Page/Party
®
or public address systems requiring redundant alarm tone/speech generators. They work in
conjunction with the GAI-Tronics Model 10959-105, -106, -207, and -208 Audio Messenger Interface
(AMI) units. The AMI acts as the alarm tone/speech generator to produce emergency tones and/or pre-
recorded speech messages. Refer to Pub. 42004-399 for more information on the Model 10959-105 and -
106 AMIs and Pub. 42004-404 for Models 10959-207 and -208 AMIs.
The ARC and AMI devices can be connected in two different configurations depending on the system
requirements. If both AMIs are to be installed at the same location, one Model 10962-002 ARC Module
can be used to control both AMIs. Refer to Figure 3. If the AMIs are to be installed at separate locations,
one Model 10960-001 ARC Module is required at each location. Each ARC will control its respective
AMI. Refer to Figure 4.
In either configuration, one AMI acts as the “active” alarm generator and the other AMI acts as the “back-
up.” The ARC module(s) control which AMI is active and which is back-up.
During normal alarm operation, input contacts are applied simultaneously to both the active and back-up
AMIs. The ARC module(s) allow only the active generator to play the tone/speech message over the
system speakers. The back-up AMI is held in standby mode to prevent audio mixing of the two AMI
tone/speech messages.
In the event of a failure of the active AMI, the back-up AMI becomes active and plays its tone/speech
message over the system speakers.
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - General Information

Pub. 42004-708L2B GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA 19540 USA 610-777-1374  800-492-1212  Fax: 610-796-5954 VISIT

Page 2 - Hardware Configuration

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 10 of 17 f:\standard ioms - current release\42004 instr. manu

Page 3 - Block Diagrams

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 11 of 17 f:\standard ioms - current release\42004 instr. manu

Page 4

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 12 of 17 f:\standard ioms - current release\42004 instr. manu

Page 5 - Installation

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 13 of 17 f:\standard ioms - current release\42004 instr. manu

Page 6

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 14 of 17 f:\standard ioms - current release\42004 instr. manu

Page 7

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 15 of 17 f:\standard ioms - current release\42004 instr. manu

Page 8 - System Terminals

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 16 of 17 f:\standard ioms - current release\42004 instr. manu

Page 9 - Output Function Notes

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 17 of 17 f:\standard ioms - current release\42004 instr. manu

Page 10 - Ethernet Receptacle

(Rev. 10/06)WarrantyEquipment. GAI-Tronics warrants for a period of one (1) year from the date of shipment, that anyGAI-Tronics equipment supplied he

Page 11

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 2 of 17 f:\standard ioms - current release\42004 instr. manua

Page 12 - Operation

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 3 of 17 f:\standard ioms - current release\42004 instr. manua

Page 13 - LCD Visual Indicators

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 4 of 17 f:\standard ioms - current release\42004 instr. manua

Page 14 - Maintenance

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 5 of 17 f:\standard ioms - current release\42004 instr. manua

Page 15 - ARC Embedded Web Page

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 6 of 17 f:\standard ioms - current release\42004 instr. manua

Page 16 - Function Meaning

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 7 of 17 f:\standard ioms - current release\42004 instr. manua

Page 17 - Specifications

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 8 of 17 f:\standard ioms - current release\42004 instr. manua

Page 18 - Return Policy

Pub. 42004-708L2B Model 10962-001 and 10962-002 AMI Redundant Controller Modules Page: 9 of 17 f:\standard ioms - current release\42004 instr. manua